Multiplex drain/overflow Visign M9
for standard bathtub, water level increase plus 5 cm
Trade mark rights exist for this document, further information can be found at viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and sanitary professionals and trained personnel
Operators
Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns against possible life-threatening injury.
This symbol warns against possible serious injury.
This symbol warns against possible injury.
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at viega.com/standards .
Risk of damage due to unsuitable liquids.
To avoid damaging the drain, only introduce the following liquids:
Typical household wastewater with temperatures up to 95 °C
The pH value must be higher than 4 but lower than 10
The Multiplex drain/overflow is a combined drain and overflow for bathtubs with a 52 mm drain hole.
The drain/overflow is suitable for standard bathtubs with the drain on the head end.
Detailed information regarding all bathtub models and the corresponding Viega drains / overflows can be found in the catalogue or on the Internet.
The following components are included in the scope of delivery of the Multiplex drain / overflow:
Drainage capacity (at an accumulation height of 300 mm) Ablaufleistung |
---|
Overflow capacity (at an accumulation height of 60 mm) |
Diameter of bathtub drain hole |
Length of Bowden cable |
Length |
Height |
Dimensions and installation depth |
0.92 l/s |
0.55 l/s or 0.63 l/s |
52 mm |
1070 mm |
100–680 mm |
180–480 mm |
The accessories shown here are not included in the scope of delivery. If required, it must be purchased separately.
Multiplex extension set
It is possible to extend the odour trap below the bathtub in the case of bathtubs with a very thick floor. The extension set, model 6161.7, is available for such cases.
The following requirements exist for the mounting of the drain / overflow:
The bathtub is installed.
The drainage line is installed all the way to the bathtub.
The underside of the bathtub is accessible.
The following values are valid for L (length) and H (height):
L = 100–680
H = 180–480
The following tools are required for mounting:
socket spanner (size 14)
fine-toothed saw
flat-blade screwdriver
No additional material is required for the complete mounting of the product.
Push the rubber sleeve onto the pipe of the overflow unit.
The lower edge must be flush with the edge of the overflow pipe.
Fit the profile seal in the overflow unit.
If the wall thickness a (in the case of steel bathtubs) is less than 3 mm, insert addition seal between profile seal and bathtub.
Join flange cover and flange.
Place the sealing element on the flange.
Fit the flange into the overflow unit.
Hold the overflow unit on the overflow opening of the bathtub from the outside.
Insert the fixing screw in the flange.
Screw in fixing screw in the overflow unit.
Pliers or other tools may damage the fixing screw or the flange. Only tighten the fixing screw by hand.
Place the site protection on the flange.
Proceed as follows to mount the drain:
Place the double seal onto the drain unit in such a way that the recess is positioned above the connecting pipe.
Pull the edge of the double seal over the edge of the drain.
Hold the drain with double seal onto the drain opening from below.
Pull the upper part of the double seal through the drain hole.
Fit the valve top in the double seal.
The cross-shaped structures of the drain unit and the valve top must be positioned parallel on top of each other to ensure the full drainage capacity.
Place the fixing screw in the drain unit and tighten using the mounting aid.
After the overflow and the drain have been mounted, you must connect them both using the overflow pipe. Proceed as follows:
Requirements:
The overflow is mounted in the overflow opening.
The drain is securely mounted on the base of the bathtub.
Connections where the pipes are not inserted far enough into each other become leaky.
For this reason, maintain a minimum insertion depth of 15 mm for every connection.
Mount the overflow pipes.
Hold the pipe of the overflow unit parallel to the mounted overflow pipes and mark the positions where the drain and the overflow should be connected.
Maintain an insertion depth of at least 15 mm!
Cut the overflow pipes to the marked length and deburr.
Push the top end of the overflow pipe into the rubber sleeve.
Maintain an insertion depth of at least 15 mm!
Push the union nut, sliding ring and seal onto the bottom end of the drain elbow.
Screw the union nut on the drain unit.
Ensure that the pipes are inserted at least 1.5 cm into the sleeve and are positioned in the drain casing.
Proceed as follows to connect the drain/overflow to the wastewater system:
Requirements:
The overflow and drain units are installed on the bathtub.
The connection between overflow and drain has been made.
If the wastewater pipe only has a diameter of 40 mm, cut off drain elbow.
Push union nut, sliding ring and seal onto the drain elbow.
Ensure that the seal is positioned securely in the recess.
Screw the union nut on the drain unit.
Align the odour trap in such a way that the drain elbow can be connected to the wastewater pipe.
Push wastewater pipe in the drain elbow.
To avoid damage to the rosette and valve cone, only mount the equipment set after finishing all other work on the building site. Proceed as follows:
Set the valve cone with the help of the adjusting screw and counter with nut.
Remove red site protection.
Fit valve cone.
Fit the rotatable rosette loosely (not all the way).
To align, turn rotatable rosette as far as it will go to the left.
The valve cone closes itself.
Remove rotatable rosette.
Fit rotatable rosette with the flat side facing upwards.
The rotatable rosette is properly aligned.
The leakage test is only carried out as a visual inspection.
Check the points marked in the following drawing with particular care:
Check drain/overflow fitting for visible leaks.
The drain / overflow are controlled via the rotatable rosette on the overflow. Proceed as follows to open or close the drain:
Turn rotatable rosette to the left.
The drain closes itself.
Turn rotatable rosette to the right.
The drain opens itself.
The water level increase occurs as follows:
The water level increase is off when the rotatable rosette is pulled out.
Draining takes place directly via the drain opening behind the rotatable rosette.
The water level increase is on when the rotatable rosette is pushed in.
Draining takes place directly via the drain opening on the upper edge of the rotatable rosette.
Push the rotatable rosette towards the rim of the bathtub.
The water level increase is activated.
There are two methods of deactivating the water level increase:
Pull out rotatable rosette.
Turn rotatable rosette to the left.
The water level increase is deactivated.
Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated surfaces and therefore may not be used:
scouring agent
abrasive sponges
lime, plaster or cement dissolver
solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone. Under no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.