Odour trap
for wall-mounted assembly
Year built (from): | 2005-06-01 |
The information in this instruction manual is directed at the following groups of people:
Heating and plumbing experts and trained personnel
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The odour trap is suitable for washbasins with 1¼ inch connection.
Drainage capacity | 0.6 l/s |
DN (nominal width) outlet pipe | DN 32/40 mm |
Drain elbow connection | 1¼ |
Water seal level | 50 mm |
Requirements:
The washbasin is mounted.
The drain pipeline is installed.
Insert the odour trap.
Determine the length X of the drain elbow.
Cut the drain elbow to length and deburr it.
Coat the drain elbow with the lubricant and insert it.
Adjust the height of the odour trap.
Screw the drain elbow to the washbasin.
The leakage test is only carried out as a visual inspection. Check the drain for visible leaks.
Use household cleaner to remove coarse soiling, also around the drain unit and the odour trap. Rinse the detergent thoroughly with clear water after the prescribed exposure time. There should be no residue on the components.
Normal soap or a mild cleaning agent can be used for regular maintenance and prevention of lime scale.
Strong stains can be removed using typical household cleaner. Rinse the detergent thoroughly with clear water after the prescribed exposure time.
Dry the surfaces with a soft cloth. There should be no residue on the components.
Be careful not to damage the odour trap when cleaning the drain.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.