Connection set
for equipment
Trade mark rights exist for this document; for further information, go to viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and plumbing experts and trained personnel
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The connection set is used to fix a wall-mounted WC ceramic.
Insert the flushing pipe and the WC connection pipe into the wall opening as far as they will go.
Mark the flush pipe and the WC connection pipe on the wall opening (X1).
Insert the flushing pipe and the WC connection pipe into the openings of the WC ceramic as far as they will go.
Mark the flush pipe and the WC connection pipe at the end edge of the WC ceramic (X2).
Measure the distance (X3) between X1 and X2.
Shorten the flush pipe and the WC connection pipe by the dimension X3.
Deburr the flush pipe and the WC connection pipe.
Grease the flushing pipe and the WC connection pipe and insert them into the wall.
Fit and align the WC ceramic.
Fix the WC ceramic in the wall with the installation set.
Attach the cap to the screws.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.