Viega fitting holder
for washing machine connection
Year built (from): | 2009-03-05 |
Trade mark rights exist for this document, further information can be found at viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and sanitary professionals and trained personnel
Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns against possible life-threatening injury.
This symbol warns against possible serious injury.
This symbol warns against possible injury.
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at viega.com/standards .
Scope / Notice | Regulations applicable in Germany |
---|---|
suitable masonry walls | EN 1996‑1‑1 |
suitable concreted walls | DIN 1045 |
Scope / Notice | Regulations applicable in Germany |
---|---|
Fulfilled noise protection requirements | DIN 4109 |
Fulfilled noise protection requirements | DIN 4109 (additional sheet 2) |
Fulfilled noise protection requirements | VDI 4100 SSt I-SSt II |
The fitting holder is suitable for mounting on wall constructions pursuant to the regulations in section Regulations from section: Fields of application / Mounting conditions and is intended for use in a Steptec pre-wall construction.
The fitting holder is intended for the mounting of a washing machine connection.
The fitting holder complies with the noise insulation requirements specified in section Regulations from section: Sound protection .
With the construction height, the marked height of the upper edge of the finished floor must be observed.
The following tools are required for mounting the fitting holder:
fork or ring spanner: 8 mm / 10 mm / 17 mm / 19 mm
Phillips-tip screwdriver
The vertical rail, onto which the fitting holder is installed, must be open facing the fitting holder.
The illustration shows the mounting on the right-hand side. The fitting holder can be installed on the left-hand side with a 180°-turn.
Secure the module onto the open Steptec rail with the slot nuts supplied:
Insert the slot nut into the opening.
Push the slot nut in slightly.
Turn by 90°.
The slot nut is secured in the Steptec rail.
Align the height of the fitting holder.
Tighten the slot nut with a ring spanner (SW 17).
Tighten the second slot nut in the same way.
The fitting holder is secured on the rail framework.
Mount wall plate connection on site. Tighten with a Phillips screwdriver and a ring spanner (WS 10).
Make water connection.
Check height settings.
Make sure that the fixing ends flush with the rail framework. The fixing may extend for a maximum of 1.5 mm beyond the rail framework.
Attach odour trap. Tighten with a ring spanner (SW 8).
The interval between the drill holes is 80 mm.
Connect on the wastewater side.
Single clad pre-wall: Clad with 12.5 mm wide IFGP or 12 mm wide Aqua-KS cladding panels.
When doing so, make sure that no abutting edges converge.
Attach sealing collar.
Push the protective cap onto the thread.
Grout the abutting edges and joints with a suitable filler.
Observe the instruction manual for the cladding panels for more information.
Remove and dispose of the protective cap after tiling.
Shorten the thread to the correct length (X) with a saw.
Mount the rosette.
Attach the hose screw fitting and check for leak tightness.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.